Tools

Trace width calculator

Based on the IPC-2221 formula: I = k · ΔT0.44 · A0.725. Use it as a starting point — see the IPC-2221 vs IPC-2152 article.

—Minimum width
—Width (mil)
—Cross-section

For reference only. For high currents, special thermal environments or critical products, use IPC-2152 and/or thermal simulation, and keep a safety margin.

mil ↔ mm converter

1 mil = 0.0254 mm.